DeployedTerpasangInstalled 13 Dec 2024; faulty T/RH sensor, panel plug and battery replaced by Mar 2025Terpasang 13 Des 2024; sensor T/RH, steker panel, dan baterai yang rusak diganti hingga Mar 2025
AWS – Pekalongan
OverviewRingkasan
Weather station at the PG Sragi sugar mill in Pekalongan. One of three Subang units refurbished and relocated in Dec 2024; reads RS485 weather and soil sensors and reports to the Smartbun dashboard.Stasiun cuaca di pabrik gula PG Sragi, Pekalongan. Salah satu dari tiga unit Subang yang diperbarui dan dipindahkan pada Des 2024; membaca sensor cuaca dan tanah RS485 serta melapor ke dashboard Smartbun.
My RolePeran Saya
Raspberry Pi firmware (Modbus RTU/MQTT), sensor wiring, power monitoring and 4G uplink; planned the relocation of the Subang stations. The on-site installation and the March 2025 maintenance were done by teammatesFirmware Raspberry Pi (Modbus RTU/MQTT), wiring sensor, monitoring daya, dan uplink 4G; merencanakan pemindahan stasiun dari Subang. Instalasi di lokasi dan maintenance Maret 2025 dikerjakan rekan tim
How It WorksCara Kerja
- RS485 Modbus weather and soil sensors plus INA219 power monitorSensor cuaca dan tanah RS485 Modbus plus monitor daya INA219
- Raspberry Pi Zero W logs readings locallyRaspberry Pi Zero W menyimpan data secara lokal
- 4G USB modem with M2M IoT SIM uplinkUplink modem USB 4G dengan SIM IoT M2M
- Smartbun platform dashboard (shared with Lumajang and Bone)Dashboard platform Smartbun (bersama Lumajang dan Bone)
Key FeaturesFitur Utama
- •Temperature/humidity, rainfall and soil readings over RS485 ModbusPembacaan suhu/kelembapan, curah hujan, dan tanah melalui RS485 Modbus
- •Local data logging while offline, with automatic reconnectionLogging data lokal saat offline, dengan koneksi ulang otomatis
- •Battery and solar power monitoring via INA219Pemantauan baterai dan daya surya melalui INA219
- •Data visible to sugar mill users on the Smartbun dashboard, with history and CSV downloadData dapat dilihat pengguna pabrik gula di dashboard Smartbun, lengkap dengan riwayat dan unduhan CSV
Field Issues & FixesKendala & Solusi
The temperature/humidity sensor was found broken during installation.Sensor suhu/kelembapan ditemukan rusak saat instalasi.
Replaced with an XY-MD02 sensor and its Modbus address reconfigured.Diganti sensor XY-MD02 dan alamat Modbus-nya diatur ulang.
In March 2025 the solar panel output and battery health were both flagged as bad.Pada Maret 2025 output panel surya dan kondisi baterai sama-sama berstatus buruk.
Panel plug resoldered, battery replaced, and the software moved from rc.local to systemd.Plug panel disolder ulang, baterai diganti, dan software dipindah dari rc.local ke systemd.
The IoT SIM data quota had to be raised after the first plan (Dec 2024).Kuota data kartu IoT perlu dinaikkan setelah paket awal (Des 2024).
Upgraded to a 250 MB data plan with a 2-month deposit (purchase request, Dec 2024).Diupgrade ke paket data 250 MB dengan deposit 2 bulan (pengajuan belanja, Des 2024).
Key NumbersAngka Kunci
- InstalledTerpasang
- 13 Dec 202413 Des 2024
- Solar panelPanel surya
- 80 Wp
- BatteryBaterai
- 12 V 20 Ah
- Stations in the relocationStasiun dalam relokasi
- 3