PrototypePrototipe3 units assembled (Feb 2025); field installation not documented; unit 3 sending data after repair (Jan 2026)3 unit dirakit (Feb 2025); pemasangan lapangan tidak terdokumentasi; unit 3 kembali mengirim data setelah diperbaiki (Jan 2026)
Smart Waste Bin V3
OverviewRingkasan
Third-generation bin node, built as the 'Basic' model of the INSPIRASI WP2 research project. A 3D-printed ESP32 + ToF unit reports fill and battery data over GSM to a new dashboard with route and fill-prediction views.Node tempat sampah generasi ketiga, dibuat sebagai model 'Basic' dari proyek riset INSPIRASI WP2. Unit ESP32 + ToF dengan casing cetak 3D melaporkan data keterisian dan baterai melalui GSM ke dashboard baru yang dilengkapi tampilan rute dan prediksi keterisian.
My RolePeran Saya
ESP32 firmware (SIM800L/MQTT), sensor and power design, 3D-printed PETG case, and field troubleshooting (Jan 2026: swapped SDA/SCL wiring and a VL53L0X supply fault on unit 3). The backend, prediction service and dashboard were built by a separate web developerFirmware ESP32 (SIM800L/MQTT), desain sensor dan daya, casing PETG 3D print, serta troubleshooting lapangan (Jan 2026: kabel SDA/SCL tertukar dan masalah suplai VL53L0X di unit 3). Backend, layanan prediksi, dan dashboard dibuat oleh web developer terpisah
How It WorksCara Kerja
- VL53L0X + INA219
- ESP32 + SIM800L (GPRS)
- MQTT
- Express + Prisma + MySQL backendBackend Express + Prisma + MySQL
- FastAPI prediction serviceLayanan prediksi FastAPI
- React dashboard (map, analytics, routes)Dashboard React (peta, analitik, rute)
Key FeaturesFitur Utama
- •Single VL53L0X fill measurement reporting distance, volume and capacity %Pengukuran keterisian dengan satu VL53L0X yang melaporkan jarak, volume, dan kapasitas %
- •Battery voltage, current, power and percentage via INA219Tegangan, arus, daya, dan persentase baterai melalui INA219
- •Sensor self-check flags (ina219_avail, vl53l0x_avail) and 999/no_sensor error values in the payloadFlag self-check sensor (ina219_avail, vl53l0x_avail) dan nilai error 999/no_sensor di payload
- •Dashboard route from a full bin to the disposal site with distance and travel-time estimateRute di dashboard dari tempat sampah penuh ke lokasi pembuangan, dengan estimasi jarak dan waktu tempuh
- •Next-day fill prediction with linear regression in a FastAPI service (still on dummy data, Jan 2026)Prediksi keterisian hari berikutnya dengan regresi linear di layanan FastAPI (masih memakai data dummy, Jan 2026)
Field Issues & FixesKendala & Solusi
Unit 3's INA219 and VL53L0X were 'not found' on I²C, even after swapping sensors and cables (Jan 2026).INA219 dan VL53L0X di unit 3 'not found' di I²C, bahkan setelah sensor dan kabel diganti (Jan 2026).
SDA and SCL were swapped; correcting the wiring restored detection.Ternyata SDA dan SCL tertukar; memperbaiki wiring membuat sensor terdeteksi kembali.
The VL53L0X always read 65535 mm because it was supplied about 4.4 V.VL53L0X selalu membaca 65535 mm karena disuplai sekitar 4,4 V.
Moved the sensor's VIN to the ESP32's 3.3 V rail.Memindahkan VIN sensor ke jalur 3,3 V ESP32.
Installation waited on bins in the chosen colours (Feb 2025).Instalasi tertunda menunggu tempat sampah dengan warna yang dipilih (Feb 2025).
Used three 120 L bins (green, grey, yellow) instead of the planned 240 L.Memakai tiga tempat sampah 120 L (hijau, abu-abu, kuning) sebagai pengganti 240 L yang direncanakan.
Key NumbersAngka Kunci
- Units assembledUnit dirakit
- 3 (parts for 3 more bought)3 (komponen untuk 3 unit lagi sudah dibeli)
- Battery packPaket baterai
- 7.4 V, 6000 mAh (4 × 18650)7,4 V, 6000 mAh (4 × 18650)
- Rated battery lifeUmur baterai (rating)
- Up to 14 daysHingga 14 hari
- Active draw (measured payload)Arus aktif (payload terukur)
- 210.7 mA at 8.28 V (1.68 W)210,7 mA pada 8,28 V (1,68 W)